LED SCREEN UNION

LSU-COB-W600 · 16:9 Front-Service COB LED Display

Build a detailed indoor video wall for presentations, monitoring and brand experiences. Six fine-pitch options share a 600 × 337.5 mm cabinet with front maintenance.

Price by inquiry

16:9 cabinet
600 × 337.5 mm
Pixel pitch range
0.625–1.875 mm
Cabinet weight
4 kg
Front maintenance
100%

A common cabinet. Six levels of detail.

W600 combines flip-chip COB technology with a modular cabinet for fixed indoor installations. Start with the wall dimensions and the smallest content your audience needs to read, then compare pixel pitch, native resolution and the control system. The same cabinet footprint makes the physical layout straightforward across the range.

Front-service module access
Front-service module access

Front access for practical maintenance

Eight 150 × 168.75 mm modules form each cabinet. Modules are accessible from the viewing side with a suitable service tool, which helps when the rear of the screen is close to a wall. Plan the mounting frame, cable route and ventilation allowance with the installation drawing.

COB surface construction illustration
COB surface construction illustration

An encapsulated COB display surface

The LED emitters sit beneath a protective surface layer. This construction supports routine handling and cleaning in busy indoor environments. Specify the approved cleaning method and spare modules when planning long-term maintenance.

Rear view of a multi-cabinet assembly
Rear view of a multi-cabinet assembly

A 16:9 format that scales with the room

Combine cabinets to match your content canvas. Each cabinet is 39.75 mm deep and weighs 4 kg. Cabinets, supporting steelwork, cabling and service space all contribute to the final installation dimensions and load.

Tune image performance to the project

Use calibration to align cabinet brightness and colour, and check low-grey gradients with your own content. For filmed presentations, include the camera frame rate, shutter settings and processor in the review.

Choose around the way the screen is used

Meeting and briefing rooms

Share the seating distance, slide format and smallest spreadsheet text. Size the wall and compare pitch options around the people closest to the screen.

Control and monitoring rooms

Send the source count, dashboard layout and operating schedule. Include processor capacity, service access and spares in the system design.

Showrooms and brand spaces

Match the wall proportions to the media and viewing route. Review ambient light, content resolution and installation depth before selecting a configuration.

From a cabinet to a complete video wall

These native-resolution examples use LSU-COB-W600-P125. Each P1.25 cabinet provides 480 × 270 pixels. The dimensions below are the active display area.

Native resolution Cabinets across × high Display width × height Cabinets Cabinet mass Peak cabinet power
1080p · 1920 × 1080 4 × 4 2.4 × 1.35 m 16 64 kg 1.12 kW
4K · 3840 × 2160 8 × 8 4.8 × 2.7 m 64 256 kg 4.48 kW
8K · 7680 × 4320 16 × 16 9.6 × 5.4 m 256 1024 kg 17.92 kW

Calculated from the cabinet specifications. Figures exclude the mounting structure, controllers and other equipment. Select electrical circuits and cooling from the final system design.

Technical specifications

Compare the six W600 configurations below. Brightness and maximum power are listed per standard configuration.

Technology
Flip-chip COB
Installation environment
Indoor fixed installation
Cabinet width × height × depth
600 × 337.5 × 39.75 mm
Module width × height
150 × 168.75 mm
Modules per cabinet
8
Cabinet weight
4 kg
Service access
Front
Low-voltage power-supply output
3.8 V / 30 A
LSU model Pixel pitch (mm) Cabinet pixels Brightness (cd/m²) Peak power (W/cabinet) Scan
LSU-COB-W600-P0625 0.625 960 × 540 600 92 1/60
LSU-COB-W600-P078 0.78 768 × 432 600 85 1/48
LSU-COB-W600-P09375 0.9375 640 × 360 600 75 1/54
LSU-COB-W600-P125 1.25 480 × 270 600 70 1/60
LSU-COB-W600-P156 1.56 384 × 216 600 70 1/54
LSU-COB-W600-P1875 1.875 320 × 180 550 65 1/40

Pixel pitches are the published nominal values. Power-supply output is the low-voltage output specification. Confirm the mains input, receiving card, processor, mounting drawing and applicable compliance documents in the project quotation.

W600 selection questions

How do I choose a pixel pitch?

Start with the nearest viewing position and the smallest text or graphic on screen. A smaller pitch puts more pixels into the same wall area. Share a sample of your content so that the proposed resolution can be checked before ordering.

Can W600 create a native 4K or 8K screen?

Yes, with the appropriate cabinet count and pixel pitch. At P1.25, an 8 × 8 cabinet array delivers 3840 × 2160 pixels, while 16 × 16 delivers 7680 × 4320. The processor and source signal must support the complete canvas.

What access is needed for maintenance?

The modules are serviced from the front. Installation still needs planned access for cables, mounting fasteners and ventilation. Include the wall construction and available clearances with your inquiry.

Is W600 suitable for outdoor installation?

The configurations on this page are intended for indoor use. For open-air sites, rain exposure or direct sunlight, request an outdoor display configuration with the appropriate protection and brightness.

Can I specify higher brightness or refresh?

Include the required brightness, pitch, daily operating hours and camera requirements in your inquiry. The quotation will identify the supported drive and control configuration, brightness and refresh settings.

What should I send for a quotation?

Send the selected LSU model or desired screen dimensions, quantity, installation photos, nearest viewing distance, content type, delivery city and schedule. Pricing is provided by inquiry.

Get a configuration for your wall

Choose a model below and tell us the wall dimensions and delivery city. Add viewing distance, content sources and installation photos when available.

Price by inquiry