LED Display Knowledge: Selection, Control & Site Planning

Make the specification fit the audience, content and site. These planning notes explain what to compare; the exact model datasheet and approved system drawing remain the basis for equipment selection.

Reviewed 20 November 2026 · LED Screen Union

How do pixel pitch and viewing distance relate?

Pixel pitch is the distance between adjacent pixel centres. A smaller pitch gives more pixels within the same active area, but a simple pitch-to-distance rule does not guarantee readable text. Check the smallest text, nearest viewer, farthest viewer and ambient light with real content. For a 4,800 × 2,700 mm active display at 1.5 mm pitch, the nominal calculation is 3,200 × 1,800 pixels (5.76 million). Confirm the actual cabinet grid before choosing a controller.

COB, GOB or SMD: what should you compare?

SMD describes packaged LEDs mounted on the board; COB places LED chips directly on a substrate. GOB is a protective coating approach, not a substitute for a complete cabinet protection rating. Compare surface reflections, low-brightness image quality, module repair procedure, spare-module compatibility and the exact product specification. Do not infer outdoor suitability, waterproofing or lifetime from a technology label alone.

How do you size an LED controller?

Start with total pixels, then check maximum width and height, load per output port, frame rate, bit depth, input connectors, receiving cards and backup routing. A headline pixel capacity is not a complete compatibility check. VX1000, VX600 and VX400 are different models: use their separate datasheets. For scheduled signage, distinguish a multimedia player from a live video processor, and record how content will be updated and recovered after a network interruption.

What changes for Dubai and Gulf installations?

Survey direct sunlight, dust exposure, ventilation, coastal conditions, service access and operating hours at the actual site. Compare the declared operating-temperature range and front/rear protection ratings for the selected cabinet. Check daylight visibility and a suitable night setting; more brightness is not always better. Structural, electrical and signage approvals depend on the location and must be confirmed by the responsible local professionals. Confirm destination, stock and dispatch timing in the quotation.

How do you estimate energy consumption?

Energy in kWh equals average measured power in kW multiplied by operating hours. Maximum rated power is used for the electrical design; it is not the same as typical consumption. Record screen brightness, content, daily schedule and the power of controllers and cooling. For example, a measured average system load of 2 kW for 10 hours uses 20 kWh. This is an arithmetic example, not a performance claim for a product.

Source documents & related reading

Product documents · Installation & maintenance

Ask the Dubai team

Send your model, project location and question. Availability, installation scope and warranty terms are confirmed in the written quotation.

Ask the Dubai team